Why Utah Parking Structures Need Traffic Coatings
Freeze-thaw cycles and deicing salts are hard on Utah parking decks. How traffic coatings protect the concrete and rebar, and when a deck needs one.
Below-grade waterproofing
Dampproofing and waterproofing are not interchangeable. How to tell which one a Utah foundation needs, and where below-grade systems usually fail.
On a set of construction drawings, “dampproofing” and “waterproofing” can look like a one-word difference. Below grade, they are two very different levels of protection — and choosing the wrong one is one of the most expensive mistakes an owner can make, because the membrane is buried the day the backfill goes in.
This article explains the difference, when each one is appropriate, and the details that decide whether a below-grade system stays dry in Utah conditions.
Dampproofing slows the movement of moisture vapor through a wall. It is typically a thin bituminous coating sprayed or rolled onto the outside of the foundation. It is not designed to resist liquid water under pressure.
Waterproofing is a membrane system designed to keep out liquid water, including water pushing against the wall under hydrostatic pressure. It is thicker, continuous, and detailed at every corner, joint and penetration.
If the space below grade will be occupied, finished, used for parking, or house mechanical and electrical equipment, it should be waterproofed.
Soil holds water. After a storm, during spring snowmelt, or anywhere the water table sits close to the bottom of the foundation, water builds up against the wall. That water has weight, and its pressure increases with depth. A dampproofing coating was never designed for that load; a waterproofing membrane was.
When dampproofing is asked to do a waterproofing job, the first sign is usually efflorescence — white mineral deposits on the inside face of the wall — followed by damp spots at cold joints and tie holes, and finally active leaks. By then the wall is backfilled and the fix is either excavation or interior injection.
See it in section
01 / 06
After storms and snowmelt, water in the soil pushes against the wall. That push is hydrostatic pressure.
02 / 06
A thin dampproofing coat slows soil moisture, but it is not built for water under pressure. Water finds cracks and joints.
03 / 06 GXS
A continuous membrane bonded to the wall and wrapped onto the footing resists water under pressure.
04 / 06 GXS
A dimpled board protects the membrane during backfill and gives water a clear path down.
05 / 06
A perforated drain at the footing carries the water away, so the pressure on the wall drops.
06 / 06
Backfill and a grade that slopes away from the building finish the system. The basement stays dry.
A geotechnical report will usually describe groundwater conditions. If it notes groundwater within a few feet of the lowest slab, or if the design includes occupied space below grade, plan on waterproofing.
There is no single best product. The right system depends on access, pressure, schedule and budget.
| System | Where it fits |
|---|---|
| Fully adhered sheet membranes | Positive-side walls with good access; uniform factory thickness |
| Fluid-applied membranes | Complex geometry and many penetrations; seamless |
| Pre-applied (blindside) membranes | Walls poured against shoring where the outside face is never reachable |
| Bentonite composites | Below-slab and blindside conditions with confinement |
| Crystalline systems | Waterproofing the concrete itself, as an admixture or surface treatment |
Most commercial projects combine more than one: for example, a blindside membrane on the shoring walls, an under-slab membrane, and a crystalline admixture in an elevator pit.
In our experience, membrane fields rarely fail on their own. Leaks almost always begin at the details:
That is why a good installer flashes and details the corners, penetrations and joints first, and installs the field membrane second.
When water is already coming in, excavating to reach the outside of the wall is slow, disruptive and expensive. In most cases the leak can be stopped from the inside:
See our waterproofing service for how we handle existing buildings.
That last question matters more than most people expect. When one contractor owns both sides of that transition, it is far less likely to be missed.
Dampproofing is a moisture retarder. Waterproofing is a barrier against liquid water under pressure. For occupied space below grade in Utah, specify waterproofing, choose a system that fits the access and conditions, and make sure the details are installed by a certified crew.
If you have a project in design or a foundation that is already leaking, send us the drawings or photos and our estimating team will recommend a system.
Only where there is no chance of water under pressure against the wall and the space below grade is not occupied or finished. Occupied basements, parking levels and elevator pits should be waterproofed.
Building codes require waterproofing where a high water table or severe soil-water conditions are known to exist, and dampproofing elsewhere. Project specifications and the use of the space often call for waterproofing even where the code minimum is dampproofing.
Yes. Most leaks through cracks, cold joints and tie holes can be stopped from the inside with polyurethane injection, which avoids excavation.
Questions about a project? Call (801) 707-4205 or email bids@guaranteedxs.com.
Send drawings, specs or a few photos. Our estimating team replies within one business day.